Efisiensi Penggunaan Plat Cendawan Terhadap Plat KonvensionalPada Gedung Pascasarjana Ums

Redesign of Pascasarjana UMS Building by using flat slab aims to obtain the efficiency need of concrete material and steel reinforcement. The calculations was based on SNI-2847-2013 code and the material properties was remained (i.e.) f'c = 18,675 MPa, fyl = 400 MPa, and fyv = 240 MPa. The stru...

Full description

Saved in:
Bibliographic Details
Main Authors: Agia, Vinca Rosea (Author), , Dr. Mochamad Solikin (Author), , Ir. H. Ali Asroni, MT (Author)
Format: Book
Published: 2016.
Subjects:
Online Access:Connect to this object online
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repoums_42899
042 |a dc 
100 1 0 |a Agia, Vinca Rosea  |e author 
700 1 0 |a , Dr. Mochamad Solikin  |e author 
700 1 0 |a , Ir. H. Ali Asroni, MT  |e author 
245 0 0 |a Efisiensi Penggunaan Plat Cendawan Terhadap Plat KonvensionalPada Gedung Pascasarjana Ums 
260 |c 2016. 
500 |a https://eprints.ums.ac.id/42899/34/NASKAH%20PUBLIKASI.pdf 
500 |a https://eprints.ums.ac.id/42899/3/HALAMAN%20DEPAN.pdf 
500 |a https://eprints.ums.ac.id/42899/4/BAB%201.pdf 
500 |a https://eprints.ums.ac.id/42899/9/BAB%202.pdf 
500 |a https://eprints.ums.ac.id/42899/12/BAB%203.pdf 
500 |a https://eprints.ums.ac.id/42899/13/BAB%204.pdf 
500 |a https://eprints.ums.ac.id/42899/17/BAB%205.pdf 
500 |a https://eprints.ums.ac.id/42899/18/BAB%206.pdf 
500 |a https://eprints.ums.ac.id/42899/19/BAB%207.pdf 
500 |a https://eprints.ums.ac.id/42899/27/DAFTAR%20PUSTAKA.pdf 
500 |a https://eprints.ums.ac.id/42899/28/LAMPIRAN.pdf 
500 |a https://eprints.ums.ac.id/42899/29/SURAT%20PERNYATAAN%20PUBLIKASI%20KARYA%20ILMIAH.pdf 
520 |a Redesign of Pascasarjana UMS Building by using flat slab aims to obtain the efficiency need of concrete material and steel reinforcement. The calculations was based on SNI-2847-2013 code and the material properties was remained (i.e.) f'c = 18,675 MPa, fyl = 400 MPa, and fyv = 240 MPa. The structure analyses were carried out using ETABS 2015, Microsoft Excel 2007, and AutoCAD 2016 was used to draw the detail results of redesign. The results are edge beam having dimension of 300x500 mm with longitudinal reinforcement of D12 and shear reinforcement of 2ϕ8-220. Column is redesign having dimension of 400x400 mm with longitudinal reinforcement of D16 and shear reinforcement of 2ϕ10-170. Flat slab is redesign having dimension of 150 mm and reinforcement of D10. Last, drop panel is redesign having dimension of 1500x1500x100 mm and reinforcement of D12. The volume of concrete after redesign is 109,17 m3 for the first floor. Comparing to volume of existing building of 154,05 m3, the redesign obtains efficiency value of 0,71. Meanwhile the volume after redesin of steel reinforcement is 5.187,80 kg for the first floor. Comparing the existing building of 27.666,64 kg, the redesign obtains efficiency value of 0,19. 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
690 |a TA Civil Engineering 
655 7 |a Thesis  |2 local 
655 7 |a NonPeerReviewed  |2 local 
787 0 |n https://eprints.ums.ac.id/42899/ 
787 0 |n S100130040 
856 \ \ |u https://eprints.ums.ac.id/42899/  |z Connect to this object online