Uji Karakteristik Hipotesis Bangunan Rumah Tinggal yang Memanfaatkan Pendinginan Evaporasi dengan Computational Fluids Dynamics (CFD)

Air conditioning in housing is required to obtain thermal comfort zone, especially at urban areas that have problems with the limitations of land. One of alternative room air conditioning (AC) that environmently-friendly to reduce refrigeration system is evaporative cooling system. The aim of the re...

Full description

Saved in:
Bibliographic Details
Main Authors: Nanda, Riski Yoga (Author), , Ir. H. Sarjito, MT., Ph.D (Author)
Format: Book
Published: 2016.
Subjects:
Online Access:Connect to this object online
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repoums_48116
042 |a dc 
100 1 0 |a Nanda, Riski Yoga  |e author 
700 1 0 |a , Ir. H. Sarjito, MT., Ph.D.  |e author 
245 0 0 |a Uji Karakteristik Hipotesis Bangunan Rumah Tinggal yang Memanfaatkan Pendinginan Evaporasi dengan Computational Fluids Dynamics (CFD) 
260 |c 2016. 
500 |a https://eprints.ums.ac.id/48116/24/naspub%20fixx.pdf 
500 |a https://eprints.ums.ac.id/48116/25/HALAMAN%20AWAL.pdf 
500 |a https://eprints.ums.ac.id/48116/7/BAB%20I.pdf 
500 |a https://eprints.ums.ac.id/48116/10/BAB%20II.pdf 
500 |a https://eprints.ums.ac.id/48116/11/BAB%20III.pdf 
500 |a https://eprints.ums.ac.id/48116/15/BAB%20IV.pdf 
500 |a https://eprints.ums.ac.id/48116/18/BAB%20V.pdf 
500 |a https://eprints.ums.ac.id/48116/21/DAFTAR%20PUSTAKA.pdf 
500 |a https://eprints.ums.ac.id/48116/22/Lampiran.pdf 
500 |a https://eprints.ums.ac.id/48116/23/PERNYATAAN%20PUBLIKASI%20ILMIAH%20PERPUS.pdf 
520 |a Air conditioning in housing is required to obtain thermal comfort zone, especially at urban areas that have problems with the limitations of land. One of alternative room air conditioning (AC) that environmently-friendly to reduce refrigeration system is evaporative cooling system. The aim of the research is to investigate characteristic of air conditioning inside the house wich utilize evaporative cooling system using Computational fluids dynamics (CFD ). The research was done by describing 3 different times which are 09.00-10.00 (in the morning), 12.00-13.00 (at noon) and 19.00-20.00 (at night) with incoming air in different properties. The air characteristic test was done by measuring velocity of the wind, relative humidity (RH) and temperatures at 28 positions of measurement cup (PU), where PU were spreaded at 3 places, (1) in front of the house; (2) at the interior; and (3) at the exterior. The measurement was conducted by making square plane of 2x2m with high of 1.5 m above floor of 28 PU. CFD simulation results showed that the cooling effect evaporative felt on the 1st floor with the average temperature reduction of 1.5 oC from the ambient temperature and increase RH of 6.75 % from ambient RH. While the vertical ventilation work effectively in supporting air circulation. The movement of the wind can be felt throughout the house with the average velocity of 0,175 m/s. Key Words : Comfort zone, Evaporative cooling, CFD 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
690 |a TA Civil Engineering 
690 |a TD Environmental technology. Sanitary engineering 
690 |a TJ Mechanical engineering and machinery 
690 |a TX Home economics 
655 7 |a Thesis  |2 local 
655 7 |a NonPeerReviewed  |2 local 
787 0 |n https://eprints.ums.ac.id/48116/ 
787 0 |n D200120054 
856 \ \ |u https://eprints.ums.ac.id/48116/  |z Connect to this object online