Keefektifan Em-4 (Effective Microorganism-4) Dalam Menurunkan Chemical Oxygen Demand (Cod) Limbah Cair Industri Batik

Based on the results of examination of COD in industrial waste water Nggemblegan Village sub district Kalikotes batik Klaten exceeds standard quality raw wastewater Perda Jateng No. 5 in 2012 that is 482.5 mg/l. purpose of this research is to analyse the effectiveness of EM-4 in lowering levels of C...

Full description

Saved in:
Bibliographic Details
Main Authors: Ramlan, Muh (Author), , Dwi Astuti, M. Kes (Author)
Format: Book
Published: 2017-04-19.
Subjects:
Online Access:Connect to this object online
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repoums_52082
042 |a dc 
100 1 0 |a Ramlan, Muh  |e author 
700 1 0 |a , Dwi Astuti, M. Kes.  |e author 
245 0 0 |a Keefektifan Em-4 (Effective Microorganism-4) Dalam Menurunkan Chemical Oxygen Demand (Cod) Limbah Cair Industri Batik 
260 |c 2017-04-19. 
500 |a https://eprints.ums.ac.id/52082/1/NASKAH%20PUBLIKASI.pdf 
500 |a https://eprints.ums.ac.id/52082/12/HALAMAN%20DEPAN%20NEW.pdf 
500 |a https://eprints.ums.ac.id/52082/3/BAB%20I.pdf 
500 |a https://eprints.ums.ac.id/52082/4/BAB%20II.pdf 
500 |a https://eprints.ums.ac.id/52082/5/BAB%20III.pdf 
500 |a https://eprints.ums.ac.id/52082/6/BAB%20IV.pdf 
500 |a https://eprints.ums.ac.id/52082/7/BAB%20V.pdf 
500 |a https://eprints.ums.ac.id/52082/8/BAB%20VI.pdf 
500 |a https://eprints.ums.ac.id/52082/9/DAFTAR%20PUSTAKA.pdf 
500 |a https://eprints.ums.ac.id/52082/10/LAMPIRAN.pdf 
500 |a https://eprints.ums.ac.id/52082/11/SURAT%20PERNYATAAN%20PUBLIKASI%20KARYA%20ILMIAH.pdf 
520 |a Based on the results of examination of COD in industrial waste water Nggemblegan Village sub district Kalikotes batik Klaten exceeds standard quality raw wastewater Perda Jateng No. 5 in 2012 that is 482.5 mg/l. purpose of this research is to analyse the effectiveness of EM-4 in lowering levels of COD of waste liquid batik industry. Experimental method used with pretest-posttest design with control group. The number of samples used is 12 litres, each treatment takes 1 liter of waste with 3 repetitions. The results of the laboratory test on the levels of COD, controls an average of 447.3 mg/l, and in the treatment group 1 ml/l, 2 l, and ml/3 ml/l COD levels an average of 393.2 mg/l, 302.6/l, mg 280.2 mg/l. dose effect on the decline of COD in the dose of 3 ml/l of 72,5%. The results of the anova statistical test shows (p < 0.01) there is the influence of the EM-4 against a decline in the levels of COD of waste batik. 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
546 |a en 
690 |a RA0421 Public health. Hygiene. Preventive Medicine 
655 7 |a Thesis  |2 local 
655 7 |a NonPeerReviewed  |2 local 
787 0 |n https://eprints.ums.ac.id/52082/ 
787 0 |n j410120057 
856 \ \ |u https://eprints.ums.ac.id/52082/  |z Connect to this object online