ANALISIS AUDIT ENERGI PADA SISTEM TENAGA LISTRIK DI GEDUNG FIP BARU UNIVERSITAS PENDIDIKAN INDONESIA

Energi listrik yang selama ini kita sering gunakan kebanyakan berasal dari sumber daya alam yang tidak dapat di perbarui seperti batubara, bahan bakar minyak, dll. Menurut Direktorat Jendral Ketenagalistrikan konsumsi energi listrik di indonesia mengalami kenaikan setiap tahunnya. Pada tahun 2017 ko...

Full description

Saved in:
Bibliographic Details
Main Author: Rizqi Adri Fauzan, - (Author)
Format: Book
Published: 2019-12-06.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Energi listrik yang selama ini kita sering gunakan kebanyakan berasal dari sumber daya alam yang tidak dapat di perbarui seperti batubara, bahan bakar minyak, dll. Menurut Direktorat Jendral Ketenagalistrikan konsumsi energi listrik di indonesia mengalami kenaikan setiap tahunnya. Pada tahun 2017 konsumsi energi listrik di indonesia mencapai 267,453 GWH mengalami kenaikan dibandingkan tahun 2012 yang mencapai 194,289 GWH. Di Universitan Pendidikan Indonesisa penggunaan energi listrik mengalami kenaikan dan penurunan. Pada salah satu gedung di Universitas Pendidikan Indoensia yaitu gedung FIP baru pada bulan April 2019 mengkonsumsi energi listrik sebesar 34.600 kWh yang mengalami kenaikan di bandingkan bulan Januari 2019 yang mengkonsumsi energi listrik sebesar 14.509 kWh. Dengan melakukan audit energi kita akan mengetahui tinggkat penggunaan energi listriknya memenuhi standar atau tidak. Dengan mencari Intensitas Konsumsi Energinya (IKE) akan diketahui bahwa gedung tersebut boros atau hemat dalam pemakaian energi listriknya. Pada gedung FIP baru Universitas Pendidikan Indonesia dilakukan audit guna mengetahui Intensitas Konsumsi Energinya (IKE) dan mencari peluang penghematan. Setelah dilakukan audit pada gedung FIP baru Universitas Pendidikan Indonesia didapat IKE sebesar 26,41 kWh/m2 per tahun. Berdasarkan perhitungan tersebut dapat di ambil kesimpulan bahwa gedung FIP baru UPI memenuhi standar yang telah dikondisikan sebesar 240 kWh/m2/tahun. Dan pada pelaksanaan audit didapat juga peluang penghematan pada instalasi AC sebesar 127,75 PK atau sebesar 16.766,32 kWh setiap bulannya. Pada bagian penerangan sendiri terjadi evaluasi pada beberapa titik lampu setiap ruangannya. Kata kunci : Audit, IKE The electricity we have used so far mostly comes from non-renewable natural resources such as coal, fuel oil, etc. According to the Directorate General of Electricity electricity consumption in Indonesia has increased every year. In 2017 electricity consumption in Indonesia reached 267,453 GWH, an increase compared to 2012 which reached 194,289 GWH. In the Indonesian University of Education the use of electricity has increased and decreased. In one of the buildings at the Indonesian Education University, the new FIP building in April 2019 consumed 34,600 kWh of electricity which increased compared to January 2019 which consumed 14,509 kWh of electrical energy. By conducting an energy audit we will find out whether the level of use of electrical energy meets the standard or not. By searching for the Energy Consumption Intensity (IKE), it will be seen that the building is wasteful or economical in using electricity. In the new FIP building, Universitas Pendidikan Indonesia conducted an audit to find out the Energy Consumption Intensity (IKE) and look for savings opportunities. After an audit of the new FIP building Universitas Pendidikan Indonesia, IKE was obtained by 26.41 kWh / m2 per year. From these calculations it can be concluded that the new UPI FIP building meets the conditioned standard of 240 kWh / m2 / year. And in the audit it was also found that the opportunity for saving on air-conditioning installations was 127.75 PK or 16,766.32 kWh every month. In the lighting section, there were evaluations of several lighting points in each room. Keywords: Audit, IKE
Item Description:http://repository.upi.edu/44792/8/S_STE_1302017_Title.pdf
http://repository.upi.edu/44792/2/S_STE_1302017_Chapter1.pdf
http://repository.upi.edu/44792/3/S_STE_1501548_Chapter2.pdf
http://repository.upi.edu/44792/4/S_STE_1501548_Chapter3.pdf
http://repository.upi.edu/44792/5/S_STE_1302017_Chapter4.pdf
http://repository.upi.edu/44792/6/S_STE_1302017_Chapter5.pdf
http://repository.upi.edu/44792/7/S_STE_1302017_Appendix.pdf