PERANCANGAN SISTEM INSTALASI PEMIPAAN AIR BERSIH PADA GEDUNG PERKANTORAN X 37 LANTAI

Plumbing is one of the building utilities that must be considered in the construction of a building because the plumbing system can distribute clean water needed by residents in the building. The design of clean water instaIasi should pay attention to the amount of clean water needs, the volume of t...

Full description

Saved in:
Bibliographic Details
Main Author: Meilyna Andhika Maranatha, (Author)
Format: Book
Published: 2021-12-13.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repoupnvj_15718
042 |a dc 
100 1 0 |a Meilyna Andhika Maranatha, .  |e author 
245 0 0 |a PERANCANGAN SISTEM INSTALASI PEMIPAAN AIR BERSIH PADA GEDUNG PERKANTORAN X 37 LANTAI 
260 |c 2021-12-13. 
500 |a http://repository.upnvj.ac.id/15718/1/ABSTRAK.pdf 
500 |a http://repository.upnvj.ac.id/15718/3/AWAL.pdf 
500 |a http://repository.upnvj.ac.id/15718/4/BAB%201.pdf 
500 |a http://repository.upnvj.ac.id/15718/6/BAB%202.pdf 
500 |a http://repository.upnvj.ac.id/15718/5/BAB%203.pdf 
500 |a http://repository.upnvj.ac.id/15718/7/BAB%204.pdf 
500 |a http://repository.upnvj.ac.id/15718/8/BAB%205.pdf 
500 |a http://repository.upnvj.ac.id/15718/9/DAFTAR%20PUSTAKA.pdf 
500 |a http://repository.upnvj.ac.id/15718/10/RIWAYAT%20HIDUP.pdf 
500 |a http://repository.upnvj.ac.id/15718/11/LAMPIRAN.pdf 
500 |a http://repository.upnvj.ac.id/15718/12/HASIL%20PLAGIARISM.pdf 
500 |a http://repository.upnvj.ac.id/15718/2/ARTIKEL.pdf 
520 |a Plumbing is one of the building utilities that must be considered in the construction of a building because the plumbing system can distribute clean water needed by residents in the building. The design of clean water instaIasi should pay attention to the amount of clean water needs, the volume of the reservoir water tank, pump capacity, pump head, pump power and net positive suction head (NPSH). To be able to meet the needs of clean water in the design of gedun g 37 floors with a total population of 6,975 people, clean water needs of 358 m3/ day. The capacity of the water reservoir tank provided for the lower water tank (Ground Water Tank)is 120 m3 and the upper water tank (Roof Tank)is 30 m3. As a result of the design of the clean water installation, the pipe used has an inner diameter of 138 mm and an outer diameter of 200 mm, the transfer pump capacity is 1.35 m3/ minute with a pump powerof 54 kW. 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
690 |a TH Building construction 
690 |a TJ Mechanical engineering and machinery 
655 7 |a Thesis  |2 local 
655 7 |a NonPeerReviewed  |2 local 
787 0 |n http://repository.upnvj.ac.id/15718/ 
787 0 |n http://repository.upnvj.ac.id 
856 4 1 |u http://repository.upnvj.ac.id/15718/  |z Link Metadata