PEMODELAN DAN SIMULASI SISTEM PENDINGIN UDARA PADA RUANG PENUMPANG, KRU, DAN ANJUNGAN KAPAL PENUMPANG SABUK NUSANTARA

The room temperature inside the ship affects the comfort level of passengers, crew, and equipment on board, so the temperature inside the vessel is set in ISO 7547, which is a maximum of 27°C. So it is necessary to know each room's cooling loads. The cooling load includes; the size of the room,...

Full description

Saved in:
Bibliographic Details
Main Author: Yudhistira Fajar Farabi, (Author)
Format: Book
Published: 2022-06-23.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repoupnvj_18733
042 |a dc 
100 1 0 |a Yudhistira Fajar Farabi, .  |e author 
245 0 0 |a PEMODELAN DAN SIMULASI SISTEM PENDINGIN UDARA PADA RUANG PENUMPANG, KRU, DAN ANJUNGAN KAPAL PENUMPANG SABUK NUSANTARA 
260 |c 2022-06-23. 
500 |a http://repository.upnvj.ac.id/18733/1/ABSTRAK.pdf 
500 |a http://repository.upnvj.ac.id/18733/13/AWAL.pdf 
500 |a http://repository.upnvj.ac.id/18733/14/BAB%201.pdf 
500 |a http://repository.upnvj.ac.id/18733/15/BAB%202.pdf 
500 |a http://repository.upnvj.ac.id/18733/16/BAB%203.pdf 
500 |a http://repository.upnvj.ac.id/18733/17/BAB%204.pdf 
500 |a http://repository.upnvj.ac.id/18733/18/BAB%205.pdf 
500 |a http://repository.upnvj.ac.id/18733/8/DAFTAR%20PUSTAKA.pdf 
500 |a http://repository.upnvj.ac.id/18733/11/RIWAYAT%20HIDUP.pdf 
500 |a http://repository.upnvj.ac.id/18733/10/LAMPIRAN.pdf 
500 |a http://repository.upnvj.ac.id/18733/9/HASIL%20PLAGIARISME.pdf 
500 |a http://repository.upnvj.ac.id/18733/12/Artikel%20KI.pdf 
520 |a The room temperature inside the ship affects the comfort level of passengers, crew, and equipment on board, so the temperature inside the vessel is set in ISO 7547, which is a maximum of 27°C. So it is necessary to know each room's cooling loads. The cooling load includes; the size of the room, the coefficient of heat transmission, the temperature in the next room, the area exposed to heat, the coefficient of the heat source, the number of people in the room, the number of equipment that generates heat, and the number of people in the room, lighting in the room. In this study, CoolPack software is used to calculate the required cooling load, and the ADF BAS System is used to simulate the air conditioning model that has been modeled 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
690 |a TA Engineering (General). Civil engineering (General) 
690 |a TD Environmental technology. Sanitary engineering 
690 |a V Naval Science (General) 
690 |a VM Naval architecture. Shipbuilding. Marine engineering 
655 7 |a Thesis  |2 local 
655 7 |a NonPeerReviewed  |2 local 
787 0 |n http://repository.upnvj.ac.id/18733/ 
787 0 |n http://repository.upnvj.ac.id 
856 4 1 |u http://repository.upnvj.ac.id/18733/  |z Link Metadata