ANALISIS SISTEM KELAIKAN PERPIPAAN PADA GEDUNG X BERDEBIT POMPA 500 GPM DENGAN SPESIFIKASI BANGUNAN 4 LANTAI DAN TINGGI BANGUNAN 24 METER

As the development of a country or region, the limitations of the area to make buildings or high rise properties will increase. When construction a building, it is necessary to have a supporting component, the hydrant. In building buildings, several references are needed, namely SNI (Indonesian Nati...

Full description

Saved in:
Bibliographic Details
Main Author: Dwi Rizky Widianto, (Author)
Format: Book
Published: 2020-09-13.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repoupnvj_7266
042 |a dc 
100 1 0 |a Dwi Rizky Widianto, .  |e author 
245 0 0 |a ANALISIS SISTEM KELAIKAN PERPIPAAN PADA GEDUNG X BERDEBIT POMPA 500 GPM DENGAN SPESIFIKASI BANGUNAN 4 LANTAI DAN TINGGI BANGUNAN 24 METER 
260 |c 2020-09-13. 
500 |a http://repository.upnvj.ac.id/7266/1/ABSTRAK.pdf 
500 |a http://repository.upnvj.ac.id/7266/2/AWAL.pdf 
500 |a http://repository.upnvj.ac.id/7266/12/BAB%201.pdf 
500 |a http://repository.upnvj.ac.id/7266/13/BAB%202.pdf 
500 |a http://repository.upnvj.ac.id/7266/14/BAB%203.pdf 
500 |a http://repository.upnvj.ac.id/7266/15/BAB%204.pdf 
500 |a http://repository.upnvj.ac.id/7266/16/BAB%205.pdf 
500 |a http://repository.upnvj.ac.id/7266/17/DAFTAR%20PUSTAKA.pdf 
500 |a http://repository.upnvj.ac.id/7266/9/DAFTAR%20RIWAYAT%20HIDUP.pdf 
500 |a http://repository.upnvj.ac.id/7266/10/LAMPIRAN.pdf 
500 |a http://repository.upnvj.ac.id/7266/18/ARTIKEL%20KI.pdf 
520 |a As the development of a country or region, the limitations of the area to make buildings or high rise properties will increase. When construction a building, it is necessary to have a supporting component, the hydrant. In building buildings, several references are needed, namely SNI (Indonesian National Standard) and NFPA (National Fire Protection Association). Aspects seen from this study include the thickness of the pipe according to the standard and calculating the safety factor based on the working pressure that occurs in the building, then proceed with the calculation of the maximum farthest distance generated at a 500 gpm pump, from previous data the results obtained at Return calculation to determine the highest speed based on the height of the building seen in the piping system, then calculate the branching and support required on the building's hydrant pipe. Based on the author's analysis, Building X still has many shortcomings, such as a reservoir reservoir that should have a volume of 85,171 m2, but the designer only designs 60 m2. In addition, the pedestal on each pipe is also still considered less than ideal, the results of the analysis of the authors get the ideal pedestal is 0.246 m between one pedestal to another pedestal. 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
546 |a id 
690 |a TA Engineering (General). Civil engineering (General) 
690 |a TD Environmental technology. Sanitary engineering 
690 |a TJ Mechanical engineering and machinery 
655 7 |a Thesis  |2 local 
655 7 |a NonPeerReviewed  |2 local 
787 0 |n http://repository.upnvj.ac.id/7266/ 
787 0 |n https://repository.upnvj.ac.id 
856 4 1 |u http://repository.upnvj.ac.id/7266/  |z Link Metadata