Automatische Abstimmung der Sekundärseite eines dreiphasigen Systems zur berührungslosen induktiven Energieübertragung
In the higher power range, three-phase inductive power transfer is an auspicious option to supply electric vehicles for local public transport. Decreases in efficiency and power transfer capability caused among others by positional misalignment and temperature cannot be completely avoided during ope...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Published: |
KIT Scientific Publishing
2015
|
Series: | Karlsruher Schriftenreihe Fahrzeugsystemtechnik / Institut für Fahrzeugsystemtechnik
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_41644 | ||
005 | 20210211 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210211s2015 xx |||||o ||| 0|deu d | ||
020 | |a KSP/1000046185 | ||
020 | |a 9783731503552 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000046185 |c doi | |
041 | 0 | |a deu | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Arnold, Rinaldo |4 auth | |
245 | 1 | 0 | |a Automatische Abstimmung der Sekundärseite eines dreiphasigen Systems zur berührungslosen induktiven Energieübertragung |
260 | |b KIT Scientific Publishing |c 2015 | ||
300 | |a 1 electronic resource (IX, 206 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a Karlsruher Schriftenreihe Fahrzeugsystemtechnik / Institut für Fahrzeugsystemtechnik | |
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a In the higher power range, three-phase inductive power transfer is an auspicious option to supply electric vehicles for local public transport. Decreases in efficiency and power transfer capability caused among others by positional misalignment and temperature cannot be completely avoided during operation. An automatic retuning of the system directly faces the remaining effects of these disturbing ascendancies and ensures continuous operation in the optimal operating point. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-sa/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-sa/4.0/ | ||
546 | |a German | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a Induktive Energieübertragungcontactless power transfer | ||
653 | |a inductive power transfer | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783731503552 |7 0 |z DOAB: download the publication |
856 | 4 | 0 | |a www.oapen.org |u https://directory.doabooks.org/handle/20.500.12854/41644 |7 0 |z DOAB: description of the publication |