Automatische Abstimmung der Sekundärseite eines dreiphasigen Systems zur berührungslosen induktiven Energieübertragung

In the higher power range, three-phase inductive power transfer is an auspicious option to supply electric vehicles for local public transport. Decreases in efficiency and power transfer capability caused among others by positional misalignment and temperature cannot be completely avoided during ope...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Yazar: Arnold, Rinaldo (auth)
Materyal Türü: Elektronik Kitap Bölümü
Baskı/Yayın Bilgisi: KIT Scientific Publishing 2015
Seri Bilgileri:Karlsruher Schriftenreihe Fahrzeugsystemtechnik / Institut für Fahrzeugsystemtechnik
Konular:
Online Erişim:DOAB: download the publication
DOAB: description of the publication
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!

MARC

LEADER 00000naaaa2200000uu 4500
001 doab_20_500_12854_41644
005 20210211
003 oapen
006 m o d
007 cr|mn|---annan
008 20210211s2015 xx |||||o ||| 0|deu d
020 |a KSP/1000046185 
020 |a 9783731503552 
040 |a oapen  |c oapen 
024 7 |a 10.5445/KSP/1000046185  |c doi 
041 0 |a deu 
042 |a dc 
072 7 |a TB  |2 bicssc 
100 1 |a Arnold, Rinaldo  |4 auth 
245 1 0 |a Automatische Abstimmung der Sekundärseite eines dreiphasigen Systems zur berührungslosen induktiven Energieübertragung 
260 |b KIT Scientific Publishing  |c 2015 
300 |a 1 electronic resource (IX, 206 p. p.) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a Karlsruher Schriftenreihe Fahrzeugsystemtechnik / Institut für Fahrzeugsystemtechnik 
506 0 |a Open Access  |2 star  |f Unrestricted online access 
520 |a In the higher power range, three-phase inductive power transfer is an auspicious option to supply electric vehicles for local public transport. Decreases in efficiency and power transfer capability caused among others by positional misalignment and temperature cannot be completely avoided during operation. An automatic retuning of the system directly faces the remaining effects of these disturbing ascendancies and ensures continuous operation in the optimal operating point. 
540 |a Creative Commons  |f https://creativecommons.org/licenses/by-sa/4.0/  |2 cc  |4 https://creativecommons.org/licenses/by-sa/4.0/ 
546 |a German 
650 7 |a Technology: general issues  |2 bicssc 
653 |a Induktive Energieübertragungcontactless power transfer 
653 |a inductive power transfer 
856 4 0 |a www.oapen.org  |u https://www.ksp.kit.edu/9783731503552  |7 0  |z DOAB: download the publication 
856 4 0 |a www.oapen.org  |u https://directory.doabooks.org/handle/20.500.12854/41644  |7 0  |z DOAB: description of the publication