Multiscale Modeling of Cardiac Electrophysiology: Adaptation to Atrial and Ventricular Rhythm Disorders and Pharmacological Treatment
Multiscale modeling of cardiac electrophysiology helps to better understand the underlying mechanisms of atrial fibrillation, acute cardiac ischemia and pharmacological treatment. For this purpose, measurement data reflecting these conditions have to be integrated into models of cardiac electrophysi...
Saved in:
Main Author: | |
---|---|
Format: | Electronic Book Chapter |
Language: | English |
Published: |
KIT Scientific Publishing
2013
|
Series: | Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering
|
Subjects: | |
Online Access: | DOAB: download the publication DOAB: description of the publication |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000naaaa2200000uu 4500 | ||
---|---|---|---|
001 | doab_20_500_12854_54078 | ||
005 | 20210211 | ||
003 | oapen | ||
006 | m o d | ||
007 | cr|mn|---annan | ||
008 | 20210211s2013 xx |||||o ||| 0|eng d | ||
020 | |a KSP/1000035360 | ||
020 | |a 9783731500452 | ||
040 | |a oapen |c oapen | ||
024 | 7 | |a 10.5445/KSP/1000035360 |c doi | |
041 | 0 | |a eng | |
042 | |a dc | ||
072 | 7 | |a TB |2 bicssc | |
100 | 1 | |a Wilhelms, Mathias |4 auth | |
245 | 1 | 0 | |a Multiscale Modeling of Cardiac Electrophysiology: Adaptation to Atrial and Ventricular Rhythm Disorders and Pharmacological Treatment |
260 | |b KIT Scientific Publishing |c 2013 | ||
300 | |a 1 electronic resource (IX, 181 p. p.) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering | |
506 | 0 | |a Open Access |2 star |f Unrestricted online access | |
520 | |a Multiscale modeling of cardiac electrophysiology helps to better understand the underlying mechanisms of atrial fibrillation, acute cardiac ischemia and pharmacological treatment. For this purpose, measurement data reflecting these conditions have to be integrated into models of cardiac electrophysiology. Several methods for this model adaptation are introduced in this thesis. The resulting effects are investigated in multiscale simulations ranging from the ion channel up to the body surface. | ||
540 | |a Creative Commons |f https://creativecommons.org/licenses/by-nc-nd/4.0/ |2 cc |4 https://creativecommons.org/licenses/by-nc-nd/4.0/ | ||
546 | |a English | ||
650 | 7 | |a Technology: general issues |2 bicssc | |
653 | |a acute cardiac ischemia | ||
653 | |a parameter adaptation | ||
653 | |a pharmacological therapy | ||
653 | |a atrial fibrillation | ||
653 | |a cardiac modeling | ||
856 | 4 | 0 | |a www.oapen.org |u https://www.ksp.kit.edu/9783731500452 |7 0 |z DOAB: download the publication |
856 | 4 | 0 | |a www.oapen.org |u https://directory.doabooks.org/handle/20.500.12854/54078 |7 0 |z DOAB: description of the publication |