A finite element analysis to study the stress distribution on distal implants in an all-on-four situation in atrophic maxilla as affected by the tilt of the implants and varying cantilever lengths
Aim: The aim of this work was to evaluate stress distribution on implants in All-on-Four situation with varying distal implant angulations (30°,40°,45°) and varying cantilever lengths (4 mm, 8 mm, 12 mm, 16 mm) in atrophic maxilla using finite element analysis. Setting and Design: A in vitro study,...