An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time.

Aims: To evaluate the accuracy of two different impression materials and to evaluate the effect of time of pouring on the accuracy of impression. Materials and Methods: Four parallel implant placed in foam arch to obtain study model. Medium body addition silicone and medium body polyether are used....

Full description

Saved in:
Bibliographic Details
Main Authors: Manaf Basil Ahmed (Author), Makdad Najeeb Chakmakchi (Author)
Format: Book
Published: University of Mosul, College of Dentistry, 2016-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_07b2e2f99b6445e58f8ff6d9fac6e000
042 |a dc 
100 1 0 |a Manaf Basil Ahmed   |e author 
700 1 0 |a Makdad Najeeb Chakmakchi  |e author 
245 0 0 |a An in Vitro Study to Evaluate the Accuracy of Addition Silicone and Polyether Impression Materials after Different Pouring Time. 
260 |b University of Mosul, College of Dentistry,   |c 2016-04-01T00:00:00Z. 
500 |a 10.33899/rden.2016.160862 
500 |a 1812-1217 
500 |a 1998-0345 
520 |a Aims: To evaluate the accuracy of two different impression materials and to evaluate the effect of time of pouring on the accuracy of impression. Materials and Methods: Four parallel implant placed in foam arch to obtain study model. Medium body addition silicone and medium body polyether are used. 20 impressions of study model were taken under monophase technique, 10 by addition silicone and 10 by polyether by closed tray technique, half of them were pour after one hour and another half of the impressions were poured after 24 hours by die stone to obtain casts. By using Traveling microscope three linear measurements were measured between 4 implants and comparsime was made between distances on the model and on the casts to assess the dimensional changes of impression materials. Results: Statistical analysis of data by paired sample T-test at (p≤0.05) reveals no significant difference in the accuracy of each material after one and 24 hours and the results analyzed by independent samples T-test reveals no significant difference between materials after one and 24 hours under closed tray technique (dimensional change don't exceed 1%). Conclusions: The results appeared that there is no difference in the accuracy between addition silicone and polyether and there is no effect of time (1h-24h) on the accuracy of impression, also results showed the high dimensional stability of two materials. 
546 |a AR 
546 |a EN 
690 |a : elastomeric impression material 
690 |a accuracy of impression 
690 |a techniques for implant 
690 |a time of pouring 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Al-Rafidain Dental Journal, Vol 16, Iss 1, Pp 10-18 (2016) 
787 0 |n https://rden.mosuljournals.com/pdf_160862_a62114c2c9c477948caf781b40aa844e.html 
787 0 |n https://doaj.org/toc/1812-1217 
787 0 |n https://doaj.org/toc/1998-0345 
856 4 1 |u https://doaj.org/article/07b2e2f99b6445e58f8ff6d9fac6e000  |z Connect to this object online.