Comparison of LC-MS/MS and EMIT methods for the precise determination of blood sirolimus in children with vascular anomalies

Sirolimus (SRL) is a mammalian target of rapamycin (mTOR) inhibitor. The whole blood concentration of SRL is routinely monitored to tailor dosage and prevent toxicity. Currently, the enzyme multiplied immunoassay technique (EMIT) is often applied to perform therapeutic drug monitoring (TDM) of SRL,...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Asıl Yazarlar: Yue-Tao Zhao (Yazar), Hao-Ran Dai (Yazar), Yue Li (Yazar), Yuan-Yuan Zhang (Yazar), Hong-Li Guo (Yazar), Xuan-Sheng Ding (Yazar), Ya-Hui Hu (Yazar), Feng Chen (Yazar)
Materyal Türü: Kitap
Baskı/Yayın Bilgisi: Frontiers Media S.A., 2022-09-01T00:00:00Z.
Konular:
Online Erişim:Connect to this object online.
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_14b22f80149b40e89163fe0f9ac3d15b
042 |a dc 
100 1 0 |a Yue-Tao Zhao  |e author 
700 1 0 |a Yue-Tao Zhao  |e author 
700 1 0 |a Hao-Ran Dai  |e author 
700 1 0 |a Hao-Ran Dai  |e author 
700 1 0 |a Yue Li  |e author 
700 1 0 |a Yuan-Yuan Zhang  |e author 
700 1 0 |a Hong-Li Guo  |e author 
700 1 0 |a Xuan-Sheng Ding  |e author 
700 1 0 |a Ya-Hui Hu  |e author 
700 1 0 |a Feng Chen  |e author 
245 0 0 |a Comparison of LC-MS/MS and EMIT methods for the precise determination of blood sirolimus in children with vascular anomalies 
260 |b Frontiers Media S.A.,   |c 2022-09-01T00:00:00Z. 
500 |a 1663-9812 
500 |a 10.3389/fphar.2022.925018 
520 |a Sirolimus (SRL) is a mammalian target of rapamycin (mTOR) inhibitor. The whole blood concentration of SRL is routinely monitored to tailor dosage and prevent toxicity. Currently, the enzyme multiplied immunoassay technique (EMIT) is often applied to perform therapeutic drug monitoring (TDM) of SRL, but the cross-reactivity with various metabolites is of great concern. A more specific method is required, such as liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, no study on the method comparison of the EMIT and LC-MS/MS for the measurement of whole blood SRL concentration in children with vascular anomalies has been reported. This study developed a simple and sensitive LC-MS/MS assay for the determination of SRL. Meanwhile, consistency between LC-MS/MS and the EMIT was evaluated by linear regression and Bland-Altman analysis. Whole blood samples were deproteinized with methanol for erythrocyte lysis, and the resulting solution was injected into the LC-MS/MS system using the positive electrospray ionization mode. The multiple reaction monitoring transitions of m/z 931.7 → 864.6 and m/z 934.7 → 864.6 were used for SRL and SRL-d3 as the internal standards, respectively. The analytes were separated on a C18 column with a gradient mobile phase (0.1 mM formic acid and 0.05 mM ammonium acetate in methanol/ultrapure water). Blood samples collected from children with vascular anomalies undergoing SRL therapy were tested by EMIT and by LC-MS/MS. The linear range of LC-MS/MS was 0.500-50.0 ng/ml and that of the EMIT was 3.50-30.0 ng/ml. A significant positive correlation between the two assays was established with a regression equation described as [EMIT] = 1.281 × [LC−MS/MS] + 2.450 (r = 0.8361). Bland-Altman plots showed a mean concentration overestimation of 4.7 ng/ml [95% CI: (−3.1, 12.6)] and a positive bias of 63.1% [95% CI: (−36.1, 162.3)] generated by the EMIT more than that of by LC-MS/MS. In conclusion, the two methods were closely correlated, indicating that switching between the two methods is feasible. Considering the overestimation nature of the EMIT assay, switching from the EMIT to the LC-MS/MS method deserves close attention and necessary re-evaluation for the target therapeutic reference range, may be required when methods are switched within the same clinical laboratory or results are compared between different laboratories. 
546 |a EN 
690 |a sirolimus 
690 |a EMIT 
690 |a LC-MS/MS 
690 |a TDM 
690 |a consistency 
690 |a children 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
655 7 |a article  |2 local 
786 0 |n Frontiers in Pharmacology, Vol 13 (2022) 
787 0 |n https://www.frontiersin.org/articles/10.3389/fphar.2022.925018/full 
787 0 |n https://doaj.org/toc/1663-9812 
856 4 1 |u https://doaj.org/article/14b22f80149b40e89163fe0f9ac3d15b  |z Connect to this object online.