Balance of Drug Residence and Diffusion in Lacrimal Fluid Determine Ocular Bioavailability in In Situ Gels Incorporating Tranilast Nanoparticles
We previously designed ophthalmic formulations (nTRA) containing tranilast nanoparticles (Tra-NPs) with high uptake into ocular tissues. In this study, we used in situ gel (ISG) bases comprising combinations of pluronic F127 (F127) and methylcellulose (MC/F127), pluronic F68 (F68/F127), and Carbopol...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Book |
Published: |
MDPI AG,
2021-09-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We previously designed ophthalmic formulations (nTRA) containing tranilast nanoparticles (Tra-NPs) with high uptake into ocular tissues. In this study, we used in situ gel (ISG) bases comprising combinations of pluronic F127 (F127) and methylcellulose (MC/F127), pluronic F68 (F68/F127), and Carbopol (Car/F127), and we developed in situ gels incorporating Tra-NPs (Tra-NP-incorporated ISNGs) such as nTRA-F127, nTRA-MC/F127, nTRA-F68/F127, and nTRA-Car/F127. Moreover, we demonstrated the therapeutic effect on conjunctival inflammation using lipopolysaccharide-induced rats. Each Tra-NP-incorporated ISNG was prepared by the bead mill method, the particle size was 40-190 nm, and the tranilast release and diffusion from formulation were nTRA > nTRA-F127 > nTRA-F68/F127 > nTRA-Car/F127 > nTRA-MC/F127. In the Tra-NP-incorporated ISNGs, the tranilast residence time in the lacrimal fluid, cornea, and conjunctiva was prolonged, although the <i>C</i><sub>max</sub> was attenuated in comparison with nTRA. On the other hand, no significant difference in conjunctival inflammation between non- and nTRA-F127-instilled rats was found; however, the nTRA-F68/F127, nTRA-Car/F127, and nTRA-MC/F127 (combination-ISG) attenuated the vessel leakage, nitric oxide, and tumor necrosis factor-α expression. In particular, nTRA-F68/F127 was significant in preventing the conjunctival inflammation. In conclusion, we found that the combination-ISG base prolonged the residence time of Tra-NPs; however, Tra-NP release from the formulation was attenuated, and the <i>T</i><sub>max</sub> was delayed longer than that in nTRA. The balance of drug residence and diffusion in lacrimal fluid may be important in providing high ocular bioavailability in formulations containing solid nanoparticles. |
---|---|
Item Description: | 10.3390/pharmaceutics13091425 1999-4923 |