An in vitro study to compare the transverse strength of thermopressed and conventional compression-molded polymethylmethacrylate polymers

Statement of Problem: Acrylic resins have been in the center stage of Prosthodontics for more than half a century. The flexural fatigue failure of denture base materials is the primary mode of clinical failure. Hence there is a need for superior physical and mechanical properties. Purpose: This in v...

Full description

Saved in:
Bibliographic Details
Main Authors: Anjana Raut (Author), Polsani Laxman Rao (Author), BVJ Vikas (Author), T Ravindranath (Author), Archana Paradkar (Author), G Malakondaiah (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2013-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_588f11e83eac4bbda9cadf4c3e90230a
042 |a dc 
100 1 0 |a Anjana Raut  |e author 
700 1 0 |a Polsani Laxman Rao  |e author 
700 1 0 |a BVJ Vikas  |e author 
700 1 0 |a T Ravindranath  |e author 
700 1 0 |a Archana Paradkar  |e author 
700 1 0 |a G Malakondaiah  |e author 
245 0 0 |a An in vitro study to compare the transverse strength of thermopressed and conventional compression-molded polymethylmethacrylate polymers 
260 |b Wolters Kluwer Medknow Publications,   |c 2013-01-01T00:00:00Z. 
500 |a 0970-9290 
500 |a 1998-3603 
500 |a 10.4103/0970-9290.118006 
520 |a Statement of Problem: Acrylic resins have been in the center stage of Prosthodontics for more than half a century. The flexural fatigue failure of denture base materials is the primary mode of clinical failure. Hence there is a need for superior physical and mechanical properties. Purpose: This in vitro study compared the transverse strength of specimens of thermopressed injection-molded and conventional compression-molded polymethylmethacrylate polymers and examined the morphology and microstructure of fractured acrylic specimens. Materials and Methods: The following denture base resins were examined: Brecrystal (Thermopressed injection-molded, modified polymethylmethacrylate) and Pyrax (compression molded, control group). Specimens of each material were tested according to the American Society for Testing and Materials standard D790-03 for flexural strength testing of reinforced plastics and subsequently examined under SEM. The data was analyzed with Student unpaired t test. Results: Flexural strength of Brecrystal (82.08 ± 1.27 MPa) was significantly higher than Pyrax (72.76 ± 0.97 MPa). The tested denture base materials fulfilled the requirements regarding flexural strength (>65 MPa). The scanning electron microscopy image of Brecrystal revealed a ductile fracture with crazing. The fracture pattern of control group specimens exhibited poorly defined crystallographic planes with a high degree of disorganization. Conclusion: Flexural strength of Brecrystal was significantly higher than the control group. Brecrystal showed a higher mean transverse strength value of 82.08 ± 1.27 MPa and a more homogenous pattern at microscopic level. Based on flexural strength properties and handling characteristics, Brecrystal may prove to be an useful alternative to conventional denture base resins. 
546 |a EN 
690 |a Crazing 
690 |a ductile fracture 
690 |a flexural strength 
690 |a injection molding 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Indian Journal of Dental Research, Vol 24, Iss 3, Pp 356-362 (2013) 
787 0 |n http://www.ijdr.in/article.asp?issn=0970-9290;year=2013;volume=24;issue=3;spage=356;epage=362;aulast=Raut 
787 0 |n https://doaj.org/toc/0970-9290 
787 0 |n https://doaj.org/toc/1998-3603 
856 4 1 |u https://doaj.org/article/588f11e83eac4bbda9cadf4c3e90230a  |z Connect to this object online.