Relationships between target intraocular pressure and central corneal thickness in stabilized and non-stabilized glaucoma patients

Background: Until now, no direct relationship has been established between the target pressure and particular corneal thickness for measurements with different types of tonometers. Purpose: To establish the dependence of target intraocular pressure (IOP) on corneal thickness for Maklakoff applanatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Dmitriev S. K. (Author), Peretiagin O. A. (Author), Lazar Yu.M (Author), Tatarina Yu.A (Author)
Format: Book
Published: Ukrainian Society of Ophthalmologists, 2021-04-01T00:00:00Z.