Removal of a Trigger Cord Stuck between Bands during Endoscopic Multiple-Band Ligation for Treating Esophageal Variceal Hemorrhage

Endoscopic variceal ligation is the preferred endoscopic treatment method for esophageal variceal bleeding. The incidence of complications such as chest pain, bleeding, stricture formation, and aspiration pneumonia is low. We report a case wherein a malfunctioning multiple-band ligator could have po...

Full description

Saved in:
Bibliographic Details
Main Authors: Nam Seok Ham (Author), Danbi Lee (Author), Sung Hyun Won (Author), Jeongseok Kim (Author), Seokjung Jo (Author), Sangyoung Yi (Author), Seol So (Author)
Format: Book
Published: Korean Society of Gastrointestinal Endoscopy, 2020-03-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Endoscopic variceal ligation is the preferred endoscopic treatment method for esophageal variceal bleeding. The incidence of complications such as chest pain, bleeding, stricture formation, and aspiration pneumonia is low. We report a case wherein a malfunctioning multiple-band ligator could have potentially caused damage to the esophageal varices and massive bleeding. The equipment was safely removed using scissors and forceps. To the best of our knowledge, this is the first published report detailing the management of a case of esophageal variceal bleeding.
Item Description:2234-2400
2234-2443
10.5946/ce.2019.076