Various polymerization temperature on dimensional accuracy of orthodontic acrylic base plate
<span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>Cold curing acrylic is more porous, having more residual monomer and dimensional change. Physical property of cold curing </em><span style="fon...
Saved in:
Main Author: | |
---|---|
Format: | Book |
Published: |
Universitas Airlangga,
2007-12-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_85d415a49e1749f5aa391e687060bae0 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Elly Rusdiana |e author |
245 | 0 | 0 | |a Various polymerization temperature on dimensional accuracy of orthodontic acrylic base plate |
260 | |b Universitas Airlangga, |c 2007-12-01T00:00:00Z. | ||
500 | |a 1978-3728 | ||
500 | |a 2442-9740 | ||
500 | |a 10.20473/j.djmkg.v40.i4.p170-172 | ||
520 | |a <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>Cold curing acrylic is more porous, having more residual monomer and dimensional change. Physical property of cold curing </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>acrylic shows to have very small dimensional change resulted from imperfect polymerization process and if dimensional change occurs, </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>it would cause improper use of orthodontic appliance. Orthodontic acrylic base plate which is made of cold curing acrylic, in order to </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>achieve good result, it is suggested to use hydro flask or polyclav with water temperature 45</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">°<span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>-50</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">°<span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C and polyclav and pressure in 2-3 </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>atm during polymerization process. Even though cold curing acrylic could polymerization at room temperature, the purpose to use hydro </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>flask or polyclav is to reduce residual monomer and porosity. The purpose of the present study is to know the difference in dimensional </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>accuracy of orthodontic acrylic at various polymerization temperature. The samples of the study were 18 acrylic base plate sized 65 </em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">× <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>10 </em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">× <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>25 mm classified into 3 control groups with polymerization temperature at 30</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C, 40</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C and 50</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C. Measurement was done using </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>caliper in order to know dimensional accuracy of orthodontic acrylic. The measurement result was tabulated and One-Way ANOVA </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>test one was done with significant level 95%, the probability result 0,0055 was found which means there was significant difference </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>among each control group. LSD test showed that group I polymerization at 30</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C, group II polymerization at 40</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C, and group III </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>polymerization at 50</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">°<span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C there was significant difference. The conclusion of this study is : dimensional difference of orthodontic acrylic </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>base plate on polymerization at group I at 30</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C, group II at 40</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C, and group III at 50</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C water temperature and could achieve better </em><span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>dimensional accuracy comparing with polymerization at 50</em><span style="font-family: TimesNewRomanPSMT; font-size: 10pt; color: #231f20; font-style: normal; font-variant: normal;">° <span style="font-family: Tribune-Italic; font-size: 9pt; color: #231f20; font-style: normal; font-variant: normal;"><em>C.</em></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span></span> | ||
546 | |a EN | ||
690 | |a cold curing acrylic | ||
690 | |a dimension | ||
690 | |a polymerization | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Dental Journal, Vol 40, Iss 4, Pp 170-172 (2007) | |
787 | 0 | |n http://e-journal.unair.ac.id/index.php/MKG/article/view/1036 | |
787 | 0 | |n https://doaj.org/toc/1978-3728 | |
787 | 0 | |n https://doaj.org/toc/2442-9740 | |
856 | 4 | 1 | |u https://doaj.org/article/85d415a49e1749f5aa391e687060bae0 |z Connect to this object online. |