The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications

Heart rate variability (HRV) is a reliable indicator of health status and a sensitive index of autonomic stress reactivity. Stress negatively affects physical and psychological wellness by decreasing cardiovascular health and reducing quality of life. Wearable sensors have made it possible to track...

Full description

Saved in:
Bibliographic Details
Main Authors: Maria I. Davila (Author), Gregory F. Lewis (Author), Stephen W. Porges (Author)
Format: Book
Published: Frontiers Media S.A., 2017-11-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_8ec6b17df49e44af8a0dfba97e56f09d
042 |a dc 
100 1 0 |a Maria I. Davila  |e author 
700 1 0 |a Gregory F. Lewis  |e author 
700 1 0 |a Gregory F. Lewis  |e author 
700 1 0 |a Gregory F. Lewis  |e author 
700 1 0 |a Stephen W. Porges  |e author 
700 1 0 |a Stephen W. Porges  |e author 
245 0 0 |a The PhysioCam: A Novel Non-Contact Sensor to Measure Heart Rate Variability in Clinical and Field Applications 
260 |b Frontiers Media S.A.,   |c 2017-11-01T00:00:00Z. 
500 |a 2296-2565 
500 |a 10.3389/fpubh.2017.00300 
520 |a Heart rate variability (HRV) is a reliable indicator of health status and a sensitive index of autonomic stress reactivity. Stress negatively affects physical and psychological wellness by decreasing cardiovascular health and reducing quality of life. Wearable sensors have made it possible to track HRV during daily activity, and recent advances in mobile technology have reduced the cost and difficulty of applying this powerful technique. Although advances have made sensors smaller and lighter, some burden on the subject remains. Chest-worn electrocardiogram (ECG) sensors provide the optimal source signal for HRV analysis, but they require obtrusive electrode or conductive material adherence. A less invasive surrogate of HRV can be derived from the arterial pulse obtained using the photoplethysmogram (PPG), but sensor placement requirements limit the application of PPG in field research. Factors including gender, age, height, and weight also affect PPG-HRV level, but PPG-HRV is sufficient to track individual HRV reactions to physical and mental challenges. To overcome the limitations of contact sensors, we developed the PhysioCam (PhyC), a non-contact system capable of measuring arterial pulse with sufficient precision to derive HRV during different challenges. This passive sensor uses an off the shelf digital color video camera to extract arterial pulse from the light reflected from an individual's face. In this article, we validate this novel non-contact measure against criterion signals (ECG and PPG) in a controlled laboratory setting. Data from 12 subjects are presented under the following physiological conditions: rest, single deep breath and hold, and rapid breathing. The following HRV parameters were validated: interbeat interval (IBI), respiratory sinus arrhythmia (RSA), and low frequency HRV (LF). When testing the PhyC against ECG or PPG: the Bland-Altman plots for the IBIs show no systematic bias; correlation coefficients (all p values < 0.05) comparing ECG to PhyC for IBI and LF approach 1, while RSA correlations average 0.82 across conditions. We discuss future refinements of the HRV metrics derived from the PhyC that will enable this technology to unobtrusively track indicators of health and wellness. 
546 |a EN 
690 |a heart rate variability 
690 |a non-contact monitoring 
690 |a arterial pulse 
690 |a sensors agreement 
690 |a optics and physiology 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Frontiers in Public Health, Vol 5 (2017) 
787 0 |n http://journal.frontiersin.org/article/10.3389/fpubh.2017.00300/full 
787 0 |n https://doaj.org/toc/2296-2565 
856 4 1 |u https://doaj.org/article/8ec6b17df49e44af8a0dfba97e56f09d  |z Connect to this object online.