Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study
# Background The test battery classically used for return-to-sport (RTS) decision-making after anterior cruciate ligament (ACL) reconstruction (ACLR) may not be sufficient, as it does not include a qualitative analysis of movement. Therefore, the Landing Error Scoring System (LESS) scale was adapted...
Saved in:
Main Authors: | , , |
---|---|
Format: | Book |
Published: |
North American Sports Medicine Institute,
2022-04-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_9de1d9540d0f40b5b323599e48a48e15 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Maxime V. Measson |e author |
700 | 1 | 0 | |a Matthew P. Ithurburn |e author |
700 | 1 | 0 | |a Alexandre JM. Rambaud |e author |
245 | 0 | 0 | |a Intra-rater Reliability of a Qualitative Landing Scale for the Single-Hop Test: A Pilot Study |
260 | |b North American Sports Medicine Institute, |c 2022-04-01T00:00:00Z. | ||
500 | |a 10.26603/001c.33066 | ||
500 | |a 2159-2896 | ||
520 | |a # Background The test battery classically used for return-to-sport (RTS) decision-making after anterior cruciate ligament (ACL) reconstruction (ACLR) may not be sufficient, as it does not include a qualitative analysis of movement. Therefore, the Landing Error Scoring System (LESS) scale was adapted to a primary functional test in the typical RTS test battery: the single leg hop for distance (SHD). # Hypothesis/ Purpose The aim of this study was to determine the intra-rater reliability of the LESS scale adapted to the SHD (SHD-LESS scale) in healthy young athletes. # Study Design Reliability analysis # Methods Nineteen healthy individuals (14 men, 5 women; mean age: 22.4 years) participated in the study. Participants performed the SHD tasks on both limbs (dominant and non-dominant) using a standardized protocol in two sessions that were one week apart (single reviewer; 2-dimensional video). Intra-class correlation coefficients (ICC2,1) were used to measure the reproducibility of the scale in the dominant (dom) and non-dominant (nondom) limbs. Additionally, limb data (dom and nondom) were pooled and evaluated collectively with intra-class correlation coefficients. The Kappa coefficient was used to assess the reproducibility of each individual item of SHD-LESS scale. # Results The intra-rater reliability was good (ICC<sub>dom</sub> = 0.77; ICC<sub>nondom</sub> = 0.87; ICC<sub>pooled</sub> = 0.87) for the overall SHD-LESS scale scores. Agreement of SHD-LESS individual items ranged from 62% to 100%. Dorsiflexion at initial contact (97% agreement; kappa value=0.79) and knee valgus after landing (88% agreement; kappa value=0.65) had excellent agreement and kappa values. # Conclusion The newly-adapted SHD-LESS scale showed good intra-rater reliability overall. Further studies should evaluate the impact of using the SHD-LESS scale within the RTS test battery on outcomes in patients after ACLR. # Level of Evidence 3 | ||
546 | |a EN | ||
690 | |a Sports medicine | ||
690 | |a RC1200-1245 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n International Journal of Sports Physical Therapy, Vol 17, Iss 3 (2022) | |
787 | 0 | |n https://doi.org/10.26603/001c.33066 | |
787 | 0 | |n https://doaj.org/toc/2159-2896 | |
856 | 4 | 1 | |u https://doaj.org/article/9de1d9540d0f40b5b323599e48a48e15 |z Connect to this object online. |