The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study

Aim: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants. Due to the limited studies about the implant systems with a connection of Slip joint design, this study aimed...

Full description

Saved in:
Bibliographic Details
Main Authors: Mehrak Amjadi (Author), Azadeh Khajavi (Author), Navid Youssefi (Author), Negar Barjini (Author), Zahra Kazemi (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2021-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_adb823c48d2f4f40b19f6b600a10cb37
042 |a dc 
100 1 0 |a Mehrak Amjadi  |e author 
700 1 0 |a Azadeh Khajavi  |e author 
700 1 0 |a Navid Youssefi  |e author 
700 1 0 |a Negar Barjini  |e author 
700 1 0 |a Zahra Kazemi  |e author 
245 0 0 |a The effect of dynamic loading on bacterial microleakage of the dental implant fixture-abutment interface: An in vitro study 
260 |b Wolters Kluwer Medknow Publications,   |c 2021-01-01T00:00:00Z. 
500 |a 0972-4052 
500 |a 1998-4057 
500 |a 10.4103/jips.jips_96_21 
520 |a Aim: Bacterial micro leakage at implant-abutment interface under functional loading is an important factor, may lead to crestal bone loss and affect the long term success of dental implants. Due to the limited studies about the implant systems with a connection of Slip joint design, this study aimed to evaluate the effect of dynamic loading on bacterial leakage at the implant-abutment interface with slip joint connection. Settings and Design: In vitro- comparative study. Materials and Methods: A total of 20 implants and abutments with slip joint connections (Tapered Screw-Vent, 3.7 mm ×10 mm, Zimmer Dental, USA) was examined and depends on using functional loading were divided into two groups; loaded and unloaded. Initially, 10 μl of Brain Heart Infusion (BHI) culture broth was pipetted to the internal lumen of each implant, then the abutments were tightened to the fixtures and crowns were cemented. In the unloaded group, samples were immersed in E-Coli suspension for 5 days. In the loaded group, samples were immersed in microbial suspension under 500000 cycles using a cyclic load device. Following disconnection of fixtures and abutments, microbial samples were taken from the internal lumen of implants and colonies were counted. Data were analyzed using. Statistical Analysis Used: Mann-Whitney statistical test, SPSS version 24. Results: The mean rate of micro leakage in unloaded and loaded groups was 4000 CFU/ml and 27000 ± 31640 CFU/ml respectively. Bacterial colonies grew in 10% of unloaded samples and 50% of loaded samples. This difference was statistically significant. (P < 0.05) Conclusions: Microbial micro leakage at the implant-abutment interface with slip joint design increased significantly after functional loading. 
546 |a EN 
690 |a bacterial count 
690 |a dental implant loading 
690 |a dental implant-abutment interface 
690 |a microleakage 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n The Journal of Indian Prosthodontic Society, Vol 21, Iss 4, Pp 420-424 (2021) 
787 0 |n http://www.j-ips.org/article.asp?issn=0972-4052;year=2021;volume=21;issue=4;spage=420;epage=424;aulast=Amjadi 
787 0 |n https://doaj.org/toc/0972-4052 
787 0 |n https://doaj.org/toc/1998-4057 
856 4 1 |u https://doaj.org/article/adb823c48d2f4f40b19f6b600a10cb37  |z Connect to this object online.