A Novel Transformer-Based Approach for Simultaneous Recognition of Hand Movements and Force Levels in Amputees Using Flexible Ultrasound Transducers

Accurate hand motion intention recognition is essential for the intuitive control of intelligent prosthetic hands and other human-machine interaction systems. Sonomyography, which can detect the changes in muscle morphology and structure precisely, is a promising signal source for fine hand movement...

Full description

Saved in:
Bibliographic Details
Main Authors: Xinhao Peng (Author), Yan Liu (Author), Fangning Tan (Author), Weicen Chen (Author), Zhiyuan Liu (Author), Teng Ma (Author), Xiangxin Li (Author), Guanglin Li (Author)
Format: Book
Published: IEEE, 2023-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_b4550ee46e77496d827c4d444928f76b
042 |a dc 
100 1 0 |a Xinhao Peng  |e author 
700 1 0 |a Yan Liu  |e author 
700 1 0 |a Fangning Tan  |e author 
700 1 0 |a Weicen Chen  |e author 
700 1 0 |a Zhiyuan Liu  |e author 
700 1 0 |a Teng Ma  |e author 
700 1 0 |a Xiangxin Li  |e author 
700 1 0 |a Guanglin Li  |e author 
245 0 0 |a A Novel Transformer-Based Approach for Simultaneous Recognition of Hand Movements and Force Levels in Amputees Using Flexible Ultrasound Transducers 
260 |b IEEE,   |c 2023-01-01T00:00:00Z. 
500 |a 1558-0210 
500 |a 10.1109/TNSRE.2023.3333008 
520 |a Accurate hand motion intention recognition is essential for the intuitive control of intelligent prosthetic hands and other human-machine interaction systems. Sonomyography, which can detect the changes in muscle morphology and structure precisely, is a promising signal source for fine hand movement recognition. However, sonomyography measured by traditional rigid ultrasound probes may suffer from poor acoustic coupling because the rigid probe surfaces cannot accommodate the curvilinear shape of the human body, particularly in the case of small and irregular residual limbs in amputees. In this study, we used a self-designed lightweight, flexible, and wearable ultrasound transducer to acquire muscle ultrasound images, and proposed a sonomyography transformer (SMGT) model for simultaneous recognition of hand movements and force levels. The performance of SMGT was systematically compared to two commonly used image processing methods, HOG and Gray Gradient, as well as a deep CNN model, in simultaneously recognizing ten classes of hand/finger movements and three force levels. Additionally, ten subjects including seven non-disabled subjects and three trans-radial amputees who are the end users of prosthetic hands were recruited to evaluate the effectiveness of SMGT. Results showed that our proposed method achieved average classification accuracies of 98.4% ± 0.6% and 96.2% ± 3.0% in non-disabled subjects and amputee subjects, respectively, which are much higher than those of other methods. This study provided a valuable approach for ultrasound-based hand motion recognition that may promote the applications of intelligent prosthetic hands. 
546 |a EN 
690 |a Sonomyography 
690 |a wearable muscle ultrasound 
690 |a hand motion intention recognition 
690 |a transformer 
690 |a trans-radial amputees 
690 |a Medical technology 
690 |a R855-855.5 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
655 7 |a article  |2 local 
786 0 |n IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol 31, Pp 4580-4590 (2023) 
787 0 |n https://ieeexplore.ieee.org/document/10318819/ 
787 0 |n https://doaj.org/toc/1558-0210 
856 4 1 |u https://doaj.org/article/b4550ee46e77496d827c4d444928f76b  |z Connect to this object online.