Differences in the force system delivered by different beta-titanium wires in elaborate designs

Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA...

Full description

Saved in:
Bibliographic Details
Main Authors: Renato Parsekian Martins (Author), Sergei Godeiro Fernandes Rabelo Caldas (Author), Alexandre Antonio Ribeiro (Author), Luís Geraldo Vaz (Author), Roberto Hideo Shimizu (Author), Lídia Parsekian Martins (Author)
Format: Book
Published: Dental Press Editora, 2015-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_bd36a553c11c4eab879a50dba8f6fb33
042 |a dc 
100 1 0 |a Renato Parsekian Martins  |e author 
700 1 0 |a Sergei Godeiro Fernandes Rabelo Caldas  |e author 
700 1 0 |a Alexandre Antonio Ribeiro  |e author 
700 1 0 |a Luís Geraldo Vaz  |e author 
700 1 0 |a Roberto Hideo Shimizu  |e author 
700 1 0 |a Lídia Parsekian Martins  |e author 
245 0 0 |a Differences in the force system delivered by different beta-titanium wires in elaborate designs 
260 |b Dental Press Editora,   |c 2015-12-01T00:00:00Z. 
500 |a 2177-6709 
500 |a 10.1590/2177-6709.20.6.089-096.oar 
520 |a Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. Results: All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. Conclusion: The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends. 
546 |a EN 
546 |a PT 
690 |a Ortodontia 
690 |a Movimento dentário 
690 |a Fios ortodônticos 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dental Press Journal of Orthodontics, Vol 20, Iss 6, Pp 89-96 (2015) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512015000600089&lng=en&tlng=en 
787 0 |n https://doaj.org/toc/2177-6709 
856 4 1 |u https://doaj.org/article/bd36a553c11c4eab879a50dba8f6fb33  |z Connect to this object online.