Biomechanical stress analysis of ceramic and indirect hybrid composite endocrowns: A three-dimensional finite element analysis

Aim: The purpose of this study was to compare equivalent stresses in mandibular first molar restored with endocrowns made of ceramic and indirect composites using three-dimensional (3D)-finite element analysis (FEA). Materials and Methods: Two 3D finite element models of mandibular first molar were...