Simultaneous determination of atorvastatin and ezetimibe from combined pharmaceutical products by micellar electrokinetic capillary chromatography

Abstract A rapid and sensitive micellar electrokinetic capillary chromatography method with UV photodiode-array detection was developed for the simultaneous determination of atorvastatin and ezetimibe in fixed dose drug combination. Experimental conditions such as buffer concentration and pH, surfac...

Täydet tiedot

Tallennettuna:
Bibliografiset tiedot
Päätekijät: Blanka Székely-Szentmiklósi (Tekijä), Gabriel Hancu (Tekijä), István Székely-Szentmiklósi (Tekijä), Béla Kovács (Tekijä), Hajnal Kelemen (Tekijä)
Aineistotyyppi: Kirja
Julkaistu: Universidade de São Paulo, 2017-04-01T00:00:00Z.
Aiheet:
Linkit:Connect to this object online.
Tagit: Lisää tagi
Ei tageja, Lisää ensimmäinen tagi!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_c2f75b1b10d940a4a3cdea94d12d19fa
042 |a dc 
100 1 0 |a Blanka Székely-Szentmiklósi  |e author 
700 1 0 |a Gabriel Hancu  |e author 
700 1 0 |a István Székely-Szentmiklósi  |e author 
700 1 0 |a Béla Kovács  |e author 
700 1 0 |a Hajnal Kelemen  |e author 
245 0 0 |a Simultaneous determination of atorvastatin and ezetimibe from combined pharmaceutical products by micellar electrokinetic capillary chromatography 
260 |b Universidade de São Paulo,   |c 2017-04-01T00:00:00Z. 
500 |a 2175-9790 
500 |a 10.1590/s2175-97902017000116122 
520 |a Abstract A rapid and sensitive micellar electrokinetic capillary chromatography method with UV photodiode-array detection was developed for the simultaneous determination of atorvastatin and ezetimibe in fixed dose drug combination. Experimental conditions such as buffer concentration and pH, surfactant concentration, system temperature, applied voltage, injection parameters were optimized in order to improve the efficiency of the separation. The best results were obtained when using fused silica capillary (48 cm length X 50 µm ID) and 25 mM borate buffer electrolyte at pH 9.3 containing 25 mM SDS, + 30 kV applied voltage, 20 ºC system temperature. The separation was achieved in approximately 2 minutes, with a resolution of 7.02, the order of migration being atorvastatin followed by ezetimibe. The analytical performance of the method was verified with regard to linearity, precision, robustness and the limit of detection and quantification were calculated. 
546 |a EN 
690 |a Micellar Electrokinetic Capillary Chromatography 
690 |a Fixed Dose Drug Combination 
690 |a Atorvastatin 
690 |a Ezetimibe. 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Brazilian Journal of Pharmaceutical Sciences, Vol 53, Iss 1 (2017) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502017000100626&lng=en&tlng=en 
787 0 |n https://doaj.org/toc/2175-9790 
856 4 1 |u https://doaj.org/article/c2f75b1b10d940a4a3cdea94d12d19fa  |z Connect to this object online.