Impact of recycling on the mechanical properties of nickel-titanium alloy wires and the efficacy of their reuse after cold sterilization

OBJECTIVE: This study aimed to assess the feasibility of reusing nickel-titanium (NiTi) alloy wires after 6 weeks of intraoral use by evaluating the changes in the load-deflection properties and surface characterization of these alloy wires after cold sterilization by immersion in 2% of acidic gluta...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: Ankit Yadav (Autore), Poonam K Jayaprakash (Autore), Rajeshwar Singh (Autore), Meeta Dawer (Autore), Palash Modi (Autore), Bhumika Sehdev (Autore), Kiran K Ganji (Autore)
Natura: Libro
Pubblicazione: Wolters Kluwer Medknow Publications, 2020-01-01T00:00:00Z.
Soggetti:
Accesso online:Connect to this object online.
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!

Accesso online

Connect to this object online.

3rd Floor Main Library

Dettagli sul posseduto da 3rd Floor Main Library
Collocazione: A1234.567
Copia 1 Disponibile