Safety and efficacy of endoscopic ultrasound-guided pancreatic duct drainage using a drill dilator: a retrospective study in Japan

Background/Aims Dilation of the tract before stent deployment is a challenging step in endoscopic ultrasound-guided pancreatic duct drainage (EUS-PDD). In this study, we examined the effectiveness and safety of a novel spiral dilator, Tornus ES (Asahi Intec), for EUS-PDD. Methods This was a retrospe...

Volledige beschrijving

Bewaard in:
Bibliografische gegevens
Hoofdauteurs: Ahmed Sadek (Auteur), Kazuo Hara (Auteur), Nozomi Okuno (Auteur), Shin Haba (Auteur), Takamichi Kuwahara (Auteur), Toshitaka Fukui (Auteur), Minako Urata (Auteur), Takashi Kondo (Auteur), Yoshitaro Yamamoto (Auteur), Kenneth Tachi (Auteur)
Formaat: Boek
Gepubliceerd in: Korean Society of Gastrointestinal Endoscopy, 2024-09-01T00:00:00Z.