Determining the Optimal Workrate for Cycle Ergometer Verification Phase Testing in Males with Obesity

The aim of the present study was to assess the validity of verification phase (VP) testing and a 3 min all-out test to determine critical power (CP) in males with obesity. Nine young adult males with a body mass index (BMI) ≥ 30 kg·m<sup>−2</sup> completed a cycle ergometer ramp-style VO...

Full description

Saved in:
Bibliographic Details
Main Authors: Jenny M. Mahoney (Author), Brett R. Baughman (Author), Ailish C. Sheard (Author), Brandon J. Sawyer (Author)
Format: Book
Published: MDPI AG, 2021-02-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e4215e696c9f49ca8bd94d0deea686de
042 |a dc 
100 1 0 |a Jenny M. Mahoney  |e author 
700 1 0 |a Brett R. Baughman  |e author 
700 1 0 |a Ailish C. Sheard  |e author 
700 1 0 |a Brandon J. Sawyer  |e author 
245 0 0 |a Determining the Optimal Workrate for Cycle Ergometer Verification Phase Testing in Males with Obesity 
260 |b MDPI AG,   |c 2021-02-01T00:00:00Z. 
500 |a 10.3390/sports9020030 
500 |a 2075-4663 
520 |a The aim of the present study was to assess the validity of verification phase (VP) testing and a 3 min all-out test to determine critical power (CP) in males with obesity. Nine young adult males with a body mass index (BMI) ≥ 30 kg·m<sup>−2</sup> completed a cycle ergometer ramp-style VO<sub>2max</sub> test, four randomized VP tests at 80, 90, 100, and 105% of maximum wattage attained during the ramp test, and a 3 min all-out test. There was a significant main effect for VO<sub>2max</sub> across all five tests (<i>p</i> = 0.049). Individually, 8 of 9 participants attained a higher VO<sub>2max</sub> (L/min) during a VP test compared to the ramp test. A trend (<i>p</i> = 0.06) was observed for VO<sub>2max</sub> during the 90% VP test (3.61 ± 0.54 L/min) when compared to the ramp test (3.37 ± 0.39 L/min). A significantly higher VO<sub>2max</sub> (<i>p</i> = 0.016) was found in the VP tests that occurred below 130% of CP wattage (N = 15, VO<sub>2max</sub> = 3.76 ± 0.52 L/min) compared to those that were above (N = 21, VO<sub>2max</sub> = 3.36 ± 0.41 L/min). Our findings suggest submaximal VP tests at 90% may elicit the highest VO<sub>2max</sub> in males with obesity and there may be merit in using % of CP wattage to determine optimal VP intensity. 
546 |a EN 
690 |a maximal oxygen uptake 
690 |a true VO<sub>2max</sub> 
690 |a males with obesity 
690 |a verification phase 
690 |a critical power 
690 |a Sports 
690 |a GV557-1198.995 
655 7 |a article  |2 local 
786 0 |n Sports, Vol 9, Iss 2, p 30 (2021) 
787 0 |n https://www.mdpi.com/2075-4663/9/2/30 
787 0 |n https://doaj.org/toc/2075-4663 
856 4 1 |u https://doaj.org/article/e4215e696c9f49ca8bd94d0deea686de  |z Connect to this object online.