Agreement of measurements of Transverse Cerebellar Diameter, Femur Length and Biparietal Diameter in sonographic determining of Gestational Age of fetuses with Intrauterine Growth Restriction

Introduction: In human, the growth of the cerebellum may be less affected by Intrauterine Growth Restriction (IUGR). Then, measurement of transverse cerebellar diameter can be used as an appropriate measurement for determining the gestational age of fetus with IUGR. This study was performed with aim...

Full description

Saved in:
Bibliographic Details
Main Authors: Nazanin Farshchian (Author), Mohammad Gharib Salehi (Author), Nasim Rashidi (Author), Parisa Bahrami Kamangar (Author)
Format: Book
Published: Mashhad University of Medical Sciences, 2019-03-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e5c07b0f39c94c88b78fa8ed86d6afe1
042 |a dc 
100 1 0 |a Nazanin Farshchian  |e author 
700 1 0 |a Mohammad Gharib Salehi  |e author 
700 1 0 |a Nasim Rashidi  |e author 
700 1 0 |a Parisa Bahrami Kamangar  |e author 
245 0 0 |a Agreement of measurements of Transverse Cerebellar Diameter, Femur Length and Biparietal Diameter in sonographic determining of Gestational Age of fetuses with Intrauterine Growth Restriction 
260 |b Mashhad University of Medical Sciences,   |c 2019-03-01T00:00:00Z. 
500 |a 1680-2993 
500 |a 2008-2363 
500 |a 10.22038/ijogi.2019.12834 
520 |a Introduction: In human, the growth of the cerebellum may be less affected by Intrauterine Growth Restriction (IUGR). Then, measurement of transverse cerebellar diameter can be used as an appropriate measurement for determining the gestational age of fetus with IUGR. This study was performed with aim to evaluate the agreement of different biometric parameters such as transverse cerebellar diameter, femur length and biparietal diameter in sonographic determining of gestational age of fetuses with IUGR and comparing them. Methods: This cross sectional study was performed on 35 pregnant women with small abdomen suspected to IUGR fetuses who referred to sonography ward of Kermanshah Imam Reza Hospital in 2016. Gestational age was determined based on the LMP of patient. Ultrasound was performed for patients; gestational age was measured by Transverse Cerebellar Diameter (TCD) and other sonographic routine parameters, and then the results were compared. Data were analyzed by SPSS software (version 22) and paired t-test, Wilcoxon, Pearson and Spearman correlation coefficient. PResults: There was no significant difference between gestational age predicted by TCD parameter and LMP (P>0.05). But, gestational age determined by the parameters of BPD and Femur Length was significantly lower than gestational age based on LMP (P<0.05). Also, gestational age determined by TCD was significantly more than gestational age based on BPD and FL (P<0.05). Conclusion: Using Transverse cerebellar diameter parameters (TCD) to estimate the accurate gestational age of fetuses with intrauterine growth restriction can be safe and reliable. 
546 |a FA 
690 |a gestational age 
690 |a intrauterine growth restriction 
690 |a sonography 
690 |a transverse cerebellar diameter 
690 |a Gynecology and obstetrics 
690 |a RG1-991 
655 7 |a article  |2 local 
786 0 |n Majallah-i Zanān, Māmā̓ī va Nāzā̓ī-i Īrān, Vol 22, Iss 1, Pp 1-8 (2019) 
787 0 |n https://ijogi.mums.ac.ir/article_12834_2b413d13ec2ec634058ea041284a9728.pdf 
787 0 |n https://doaj.org/toc/1680-2993 
787 0 |n https://doaj.org/toc/2008-2363 
856 4 1 |u https://doaj.org/article/e5c07b0f39c94c88b78fa8ed86d6afe1  |z Connect to this object online.