Comparison of debonding resistance and failure type of three orthodontic band cements

Introduction: the objective of this study was to compare the debonding resistance and failure type observed in three materials used for band cementation by means of the universal testing machine and a stereomicroscope. Methods: 72 third lower molars were collected from patients who needed extraction...

Full description

Saved in:
Bibliographic Details
Main Authors: Liliana Andrea Piedra-Sarmiento (Author), María Claudia Ariza-Salas (Author), Humberto José Guzmán-Báez (Author), Fernando Zárate-Cadena (Author)
Format: Book
Published: Universidad de Antioquia, 2016-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction: the objective of this study was to compare the debonding resistance and failure type observed in three materials used for band cementation by means of the universal testing machine and a stereomicroscope. Methods: 72 third lower molars were collected from patients who needed extractions; metal bands were cemented on them with a pre-soldered tube and internal etching (Bracket USED, OrthoUSA, USA). The samples were randomly sorted out in three groups, forming a control group (zinc phosphate) and two pilot groups (resin-modified glass ionomer and polyacidmodified composite resin). All samples were subjected to a process of 2000 thermal cycles, and later to a debonding resistance test in the universal testing machine (Instron 3367 class 0.5, with 0-30 Kn load cell, USA) at a speed of 2 mm/min. The data were calculated in megapascals, taking into account the surface area of bands (mm2). Finally, to determine failure type, a visual inspection was conducted using a stereomicroscope (Stemi 2000C, Carl Zeiss, Göttingen, Germany AXIOCAM Carl Zeiss Microimaging, Göttingen, Germany). Results: no statistically significant differences were found among the three study groups in terms of debonding resistance (p value = 0.119). The most predominant failure type in the three cements occurred at the cemento-enamel interphase, with 61.1%, showing a statistically significant difference. Conclusion: zinc phosphate, resin-modified glass ionomer and polyacid-modified composite resin showed similar debonding resistance values and the most predominant failure type in the three band cementing materials occurred at the cemento-enamel interface; however, the resin-modified glass ionomer showed a lower percentage.
Item Description:https://doi.org/10.17533/udea.rfo.v28n1a5
0121-246X
2145-7670