Effects of an Animated Blood Clot Technology (Visual Clot) on the Decision-Making of Users Inexperienced in Viscoelastic Testing: Multicenter Trial

BackgroundViscoelastic test-guided coagulation management has become increasingly important in assessing hemostasis. We developed Visual Clot, an animated, 3D blood clot that illustrates raw rotational thromboelastometry (ROTEM) parameters in a user-centered and situation awareness-oriented method....

Full description

Saved in:
Bibliographic Details
Main Authors: Said, Sadiq (Author), Roche, Tadzio Raoul (Author), Braun, Julia (Author), Ganter, Micheal Thomas (Author), Meybohm, Patrick (Author), Herrmann, Johannes (Author), Zacharowski, Kai (Author), Raimann, Florian Jürgen (Author), Piekarski, Florian (Author), Rivas, Eva (Author), López-Baamonde, Manuel (Author), Spahn, Donat R (Author), Nöthiger, Christoph Beat (Author), Tscholl, David Werner (Author)
Format: Book
Published: JMIR Publications, 2021-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_e90c3dba2b7845baa5aaafe8b5ec6f4c
042 |a dc 
100 1 0 |a Said, Sadiq  |e author 
700 1 0 |a Roche, Tadzio Raoul  |e author 
700 1 0 |a Braun, Julia  |e author 
700 1 0 |a Ganter, Micheal Thomas  |e author 
700 1 0 |a Meybohm, Patrick  |e author 
700 1 0 |a Herrmann, Johannes  |e author 
700 1 0 |a Zacharowski, Kai  |e author 
700 1 0 |a Raimann, Florian Jürgen  |e author 
700 1 0 |a Piekarski, Florian  |e author 
700 1 0 |a Rivas, Eva  |e author 
700 1 0 |a López-Baamonde, Manuel  |e author 
700 1 0 |a Spahn, Donat R  |e author 
700 1 0 |a Nöthiger, Christoph Beat  |e author 
700 1 0 |a Tscholl, David Werner  |e author 
245 0 0 |a Effects of an Animated Blood Clot Technology (Visual Clot) on the Decision-Making of Users Inexperienced in Viscoelastic Testing: Multicenter Trial 
260 |b JMIR Publications,   |c 2021-05-01T00:00:00Z. 
500 |a 1438-8871 
500 |a 10.2196/27124 
520 |a BackgroundViscoelastic test-guided coagulation management has become increasingly important in assessing hemostasis. We developed Visual Clot, an animated, 3D blood clot that illustrates raw rotational thromboelastometry (ROTEM) parameters in a user-centered and situation awareness-oriented method. ObjectiveThis study aimed to evaluate the applicability of Visual Clot by examining its effects on users that are novices in viscoelastic-guided resuscitation. MethodsWe conducted an investigator-initiated, international, multicenter study between September 16, 2020, and October 6, 2020, in 5 tertiary care hospitals in central Europe. We randomly recruited medical students and inexperienced resident physicians without significant prior exposure to viscoelastic testing. The 7 participants per center managed 9 different ROTEM outputs twice, once as standard ROTEM tracings and once as the corresponding Visual Clot. We randomly presented the 18 viscoelastic cases and asked the participants for their therapeutic decisions. We assessed the performance, diagnostic confidence, and perceived workload in managing the tasks using mixed statistical models and adjusted for possible confounding factors. ResultsAnalyzing a total of 630 results, we found that the participants solved more cases correctly (odds ratio [OR] 33.66, 95% CI 21.13-53.64; P<.001), exhibited more diagnostic confidence (OR 206.2, 95% CI 93.5-454.75; P<.001), and perceived less workload (coefficient -41.63; 95% CI -43.91 to -39.36; P<.001) using Visual Clot compared to using standard ROTEM tracings. ConclusionsThis study emphasizes the practical benefit of presenting viscoelastic test results in a user-centered way. Visual Clot may allow inexperienced users to be involved in the decision-making process to treat bleeding-associated coagulopathy. The increased diagnostic confidence, diagnostic certainty, reduced workload, and positive user feedback associated with this visualization may promote the further adoption of viscoelastic methods in diverse health care settings. 
546 |a EN 
690 |a Computer applications to medicine. Medical informatics 
690 |a R858-859.7 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Journal of Medical Internet Research, Vol 23, Iss 5, p e27124 (2021) 
787 0 |n https://www.jmir.org/2021/5/e27124 
787 0 |n https://doaj.org/toc/1438-8871 
856 4 1 |u https://doaj.org/article/e90c3dba2b7845baa5aaafe8b5ec6f4c  |z Connect to this object online.