The number of patients with implantable cardiac devices (CIEDs) is rapidly increasing. One of the reason behind this phenomenon is aging population and sophisticated treatment of coronary artery disease but also new technologies are continually evolving. Indication for the implantation are changing...

Full description

Saved in:
Bibliographic Details
Main Authors: Przemysław Sawicki (Author), Piotr Małyszka (Author), Łukasz Wołowiec (Author), Bartosz Górny (Author), Małgorzata Chudzińska (Author), Walery Zukow (Author), Władysław Sinkiewicz (Author)
Format: Book
Published: Kazimierz Wielki University, 2017-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_ec5ea76bcf6d4124b7f0f19fcf4e6dec
042 |a dc 
100 1 0 |a Przemysław Sawicki  |e author 
700 1 0 |a Piotr Małyszka  |e author 
700 1 0 |a Łukasz Wołowiec  |e author 
700 1 0 |a Bartosz Górny  |e author 
700 1 0 |a Małgorzata Chudzińska  |e author 
700 1 0 |a Walery Zukow  |e author 
700 1 0 |a Władysław Sinkiewicz  |e author 
245 0 0 |a Living with an implantable cardiac device 
260 |b Kazimierz Wielki University,   |c 2017-05-01T00:00:00Z. 
500 |a 2391-8306 
500 |a 10.5281/zenodo.583335 
520 |a The number of patients with implantable cardiac devices (CIEDs) is rapidly increasing. One of the reason behind this phenomenon is aging population and sophisticated treatment of coronary artery disease but also new technologies are continually evolving. Indication for the implantation are changing following new trials results proving the reduction of  mortality and morbidity rates. With the technological development that is currently taking place, there is a growing number of electromagnetic signals which can potentially create electromagnetic interference (EMI)  with cardiac devices.  This study aims to bring closer the matter of living with cardiac device to all kind of medical staff and patients, with special regard to potential sources of electromagnetic interference and its effect on cardiac devices. The paper also updates contraindications and optimize management in a variety of "real life" situations. 
546 |a EN 
546 |a ES 
546 |a PL 
546 |a RU 
546 |a UK 
690 |a pacemaker, cardioverter - defibrykator, cardiac resynchronization therapy, ventricular assist device, electromagnetic interference 
690 |a Education 
690 |a L 
690 |a Sports 
690 |a GV557-1198.995 
690 |a Medicine 
690 |a R 
655 7 |a article  |2 local 
786 0 |n Journal of Education, Health and Sport, Vol 7, Iss 5, Pp 382-400 (2017) 
787 0 |n http://www.ojs.ukw.edu.pl/index.php/johs/article/view/4482 
787 0 |n https://doaj.org/toc/2391-8306 
856 4 1 |u https://doaj.org/article/ec5ea76bcf6d4124b7f0f19fcf4e6dec  |z Connect to this object online.