Correspondence between try-in pastes and resin cements, and color stability of bonded lithium disilicate disks

Abstract: This study investigates the color correspondence of resin cements and try-in pastes, and the color stability of bonded lithium disilicate ceramic disks. Resin composite disks were fabricated (n = 36) to serve as the background for lithium disilicate disks prepared in two thicknesses (0.5 a...

Whakaahuatanga katoa

I tiakina i:
Ngā taipitopito rārangi puna kōrero
Ngā kaituhi matua: Rafael Soares Diniz (Author), Letícia Fecury Bogéa de Albuquerque (Author), Rudys de Jesus Rodolfo Tavarez (Author), Eduardo Buozzi Moffa (Author), Andréa Dias Neves Lago (Author), Letícia Machado Gonçalves (Author)
Hōputu: Pukapuka
I whakaputaina: Sociedade Brasileira de Pesquisa Odontológica.
Ngā marau:
Urunga tuihono:Connect to this object online.
Ngā Tūtohu: Tāpirihia he Tūtohu
Kāore He Tūtohu, Me noho koe te mea tuatahi ki te tūtohu i tēnei pūkete!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_f828f80dc7c64b8c8af531c8f11e6bcf
042 |a dc 
100 1 0 |a Rafael Soares Diniz  |e author 
700 1 0 |a Letícia Fecury Bogéa de Albuquerque  |e author 
700 1 0 |a Rudys de Jesus Rodolfo Tavarez  |e author 
700 1 0 |a Eduardo Buozzi Moffa  |e author 
700 1 0 |a Andréa Dias Neves Lago  |e author 
700 1 0 |a Letícia Machado Gonçalves  |e author 
245 0 0 |a Correspondence between try-in pastes and resin cements, and color stability of bonded lithium disilicate disks 
260 |b Sociedade Brasileira de Pesquisa Odontológica. 
500 |a 1807-3107 
500 |a 10.1590/1807-3107bor-2019.vol33.0009 
520 |a Abstract: This study investigates the color correspondence of resin cements and try-in pastes, and the color stability of bonded lithium disilicate ceramic disks. Resin composite disks were fabricated (n = 36) to serve as the background for lithium disilicate disks prepared in two thicknesses (0.5 and 1.0 mm, n = 18 each). Two brands were used for try-in and cement procedures: Variolink Veneer and AllCem Veneer. For baseline, water was applied between the ceramic disks and their respective backgrounds to achieve the control group. This set was subjected to color measurement using an intraoral measurement device (T0). The try-in was inserted between background and ceramic, and this set was subjected to color measurement (T1). After adhesive procedures, the ceramic disk was placed under cement, and color measurement was performed with uncured cement (T2) and 24 h after light-curing (T3). Each set was immersed in distilled water and thermal-cycled, with color measurement being performed after 10,000 (T4) and 20,000 (T5) cycles. Color differences were calculated by CIELab (rEab) and CIEDE2000 (rE00). Data were analyzed by two-way ANOVA for repeated measurements and Tukey's test (α=5%). There was color correspondence of try-in and resin cement for the Variolink system, regardless of the ceramic thickness (p > 0.05). For the AllCem system, the thickness significantly influenced the color measurement (p < 0.001). The Variolink system also demonstrated color stability after 20,000 thermal cycles with rEab < 3.46 and rE00 < 2.25. It was concluded that the color correspondence between a try-in and its respective cement may vary according to resin cement composition. 
546 |a EN 
690 |a Resin Cements 
690 |a Color 
690 |a Ceramics 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Brazilian Oral Research, Vol 33, Iss 0 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242019000100226&lng=en&tlng=en 
787 0 |n https://doaj.org/toc/1807-3107 
856 4 1 |u https://doaj.org/article/f828f80dc7c64b8c8af531c8f11e6bcf  |z Connect to this object online.