The New Carotid Braided Stent CASPERTM RX. Single center experience in 50 cases
<p>Purpose: Carotid stenosis, as well as dissections and pseudo dissecting aneurysms are etiological factors of Ischemic stroke. A new braided double-layer Nickel titanium Stent CASPERTMRX has super elasticity, shape-memory properties, combined with re-sheathable and repositionable, improving...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Book |
Published: |
Journal of Cardiovascular Medicine and Cardiology - Peertechz Publications,
2020-05-15.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | peertech__10_17352_2455-2976_000127 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Cabral de Andrade G |e author |
700 | 1 | 0 | |a Lesczynski A |e author |
700 | 1 | 0 | |a Clímaco VM |e author |
700 | 1 | 0 | |a Pereira ER |e author |
245 | 0 | 0 | |a The New Carotid Braided Stent CASPERTM RX. Single center experience in 50 cases |
260 | |b Journal of Cardiovascular Medicine and Cardiology - Peertechz Publications, |c 2020-05-15. | ||
520 | |a <p>Purpose: Carotid stenosis, as well as dissections and pseudo dissecting aneurysms are etiological factors of Ischemic stroke. A new braided double-layer Nickel titanium Stent CASPERTMRX has super elasticity, shape-memory properties, combined with re-sheathable and repositionable, improving placement accuracy in a closed cell with flow diversion capability. To evaluate in clinical implant behavicor of in many different pathologies. </p><p>Materials and methods: It was implanted 53 CASPER-RX stents in 50 lesions (average age of 67 years; 29 men and 21 women) in different pathologies, high-grade symptomatic internal carotid artery stenosis in 43(86%) patients; and dissection in 7(4%) being: 4 dissecting pseudo aneurysms, 2 sub endothelial spontaneous dissections and 1 sub endothelial iatrogenic dissection. In all patients we used dual antiplatelet therapy, before treatment. </p><p>Results: Technical success achieved in all patients and complication rate (4%) and a 0% rate of neurological complications at 30 days. No stroke minor or restenosis after 6 months ultrasound or CT Scan examination FU. </p><p>Conclusion: CASPER™RX Stent conforms to tortuous anatomy, good wall apposition and a good conformation in tapered ICA-CCA segments in re sheathable delivery system. The very closed cells have a good result as a flow diverter. Technical success was achieved in all patients without clinical complications. However, we need long-term follow up to better assess the efficiency of this new device.</p> | ||
540 | |a Copyright © Cabral de Andrade G et al. | ||
546 | |a en | ||
655 | 7 | |a Research Article |2 local | |
856 | 4 | 1 | |u https://doi.org/10.17352/2455-2976.000127 |z Connect to this object online. |