Inference Analysis of Dry Rubber Content Capacitance Properties in Discriminating Type of Rubber Clones / Ummu Raihan Yussuf...[et al.]

This project describes the development of a capacitive sensor for measuring capacitance of the Dry Rubber Content (DRC) by using parallel plate for classification of rubber clones. Five dry rubber contents from different clones were identified: RRIM2002, RRIM2007, RRIM2008, RRIM2014 and RRIM3001. An...

Full description

Saved in:
Bibliographic Details
Main Authors: Yussuf, Ummu Raihan (Author), Hashim, Hadzli (Author), Johari, Juliana (Author), Mohd Sampian, Ahmad Faiz (Author), Abdullah, Noor Ezan (Author), Khairuzzaman, Noor Aishah (Author), Maskom, Mohamad Azrif (Author)
Format: Book
Published: Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM), 2017.
Subjects:
Online Access:Link Metadata
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 repouitm_38469
042 |a dc 
100 1 0 |a Yussuf, Ummu Raihan  |e author 
700 1 0 |a Hashim, Hadzli  |e author 
700 1 0 |a Johari, Juliana  |e author 
700 1 0 |a Mohd Sampian, Ahmad Faiz  |e author 
700 1 0 |a Abdullah, Noor Ezan  |e author 
700 1 0 |a Khairuzzaman, Noor Aishah  |e author 
700 1 0 |a Maskom, Mohamad Azrif  |e author 
245 0 0 |a Inference Analysis of Dry Rubber Content Capacitance Properties in Discriminating Type of Rubber Clones / Ummu Raihan Yussuf...[et al.] 
260 |b Faculty of Mechanical Engineering Universiti Teknologi MARA (UiTM),   |c 2017. 
500 |a https://ir.uitm.edu.my/id/eprint/38469/1/38469.pdf 
520 |a This project describes the development of a capacitive sensor for measuring capacitance of the Dry Rubber Content (DRC) by using parallel plate for classification of rubber clones. Five dry rubber contents from different clones were identified: RRIM2002, RRIM2007, RRIM2008, RRIM2014 and RRIM3001. An aluminium tape had been used as a parallel plate sensor and paired with Arduino microcontroller for the output extraction. The device measures the output in capacitance value from the capacitance sensor based on the dry rubber content samples placed in between the two plates. Statistical analysis using the SPSS software is used to analyse data for each rubber clone; in which for discrimination of data, the normality distribution was tested. The analysis of normality revealed that the data is not normally distributed. Thus, non-parametric test Kruskal-Wallis test is used. Result shows that there is a statistical significance difference of the capacitance value among the five different rubber clone groups. This is proven by significant level of Kruskal-Wallis test of less than 0.05. RRIM2002 has the highest mean rank of capacitance value followed by RRIM2008, RRIM2014, RRIM3001 and the lowest is RRIM2007. 
546 |a en 
690 |a TJ Mechanical engineering and machinery 
655 7 |a Article  |2 local 
655 7 |a PeerReviewed  |2 local 
787 0 |n https://ir.uitm.edu.my/id/eprint/38469/ 
787 0 |n https://jmeche.uitm.edu.my/ 